This equipment features:
- Computerized control
- Programmable regeneration cycles
- Up to 50% saving on salt usage
- Up to 40% saving on water used for regeneration
- Continual supply of conditioned water
Control Features - The Top Of The Class


Valve Diagnostics
( Read Only )
- Regeneration Days Ago:
- Displays how many days ago the unit last regenerated.
- In Service:
- Displays how many days the control has been in service.
- Number of Regenerations:
- Displays the number of regenerations that have taken place since the control was installed.
- Total Volume:
- Displays the total volume of water used since installation.
- Last Regeneration:
- Displays the amount of water used before the last regeneration.
- Peak Flow:
- Displays the peak flow rate since the last regeneration. This function resets back to zero after every regeneration.
- Note: Will not display when control is programmed for Volume/Pulse.
- Average Daily Volume:
- Displays the average daily water consumption.
- Capacity/System:
- If the control is programmed for Volume, the display will read CAPACITY along with the maximum volume of water to be used. When the control is programmed for hardness, the display will read SYSTEM along with the maximum grain capacity of the system.
- Hardness:
- Displays the amount of hardness programmed into the control(will not display when control is programmed for volume).
- Reserve:
- Displays whether the control is programmed for fixed or variable reserve. Note: Will not display when programmed for immediate regeneration.
- Regeneration Time:
- Displays the time of day the unit will regenerate.
- Override:
- Displays the override mode by reading OFF, or the number of days programmed into the control.
- Backwash:
- Displays the minutes of backwash programmed into the control. If the control is programmed for metric units this position will display as CYCLE 1.
- Note: Not applicable on all models.
- Brine and Rinse:
- Displays the minutes of brine and rinse programmed into the control. If the control is programmed for metric units this position will display as CYCLE 2.
- Fill and Rinse:
- Displays the minutes of fill and rinse programmed into the control. If the control is programmed for metric units this position will display as CYCLE 3. Note: Not applicable on all models.
- Units:
- Displays the mode of measurement, ENGLISH or METRIC.
- Meter:
- Displays whether the control is programmed as STANDARD METER, NO METER or VOLUME/PULSE setting.
- Capacity Volume/Hardness:
- Displays whether the control is programmed for a CAPACITY VOLUME or CAPACITY HARDNESS setting.
- Regeneration:
- Displays the programmed regeneration type. DELAYED, IMMEDIATE or DELAYED/IMMEDIATE.
- Valve Type:
- Displays the type of valve the factory programmed into the control.
- M P Resets:
- Displays how many times the programs have been reset.
- Corrupt Memory:
- For factory information only.
- 4000 VTL REV:
- For factory information only.
Programming Instructions
( End User )
- Key Buttons:
SCROLL
UP ARROW
DOWN ARROW
-
- Programming the Time of Day:
- The time of day and total gallons remaining is viewed in the display. Pressing the
SCROLL button enters the Time of Day programming mode. Once pressed the time of day will start flashing. To adjust the time, press the UP ARROW or DOWN ARROW.
-
- Holiday Program:
- To activate the holiday program press the
SCROLL button twice. Holiday will start flashing. If the control is left in this program the system will not regenerate. The holiday program ends when a flow rate greater than 1.5 GPM is measured or when the SCROLL button is pressed. In either of these cases the system regenerates immediately.
-
- Immediate Regeneration:
- To manual regenerate the system, press the
SCROLL button three times. Seconds will count down from 10 to 0 initiating regeneration. To cancel the regeneration, scroll past the cycle before the control counts down to zero. If the control reaches zero, the system will initiate regeneration.
-
- Delayed Regeneration:
- To activate, press the
SCROLL button four times. The control will display Regen at 2:00 Am. Leave the control in this program in order for this setting to activate. Note: Will not display if control is programmed for immediate regeneration. To advance the system through regeneration, press the SCROLL button. Continue past each step in the regeneration cycle until the control displays the time of day.
Note: Allow the motor to stop at each cycle before advancing.
Visual Instructions
( End User )
-
- Accessing the End-User's Level:
- Setting the Time of Day
- Holiday Mode
- Immediate Regeneration Mode
- Delayed Regeneration Mode:
-
- 1. Accessing the End-User's Level:
-
- Verify the control valve is in the service mode.
- The control will display the time of day and gallons remaining before regeneration.
- Press the SCROLL button; the control will display:
- 2. Setting the Time of Day:
-
- The control will display:
- Press the
UP ARROW or DOWN ARROW to program the time of day. Press the SCROLL button to advance to the next setting.
- 3. Holiday Mode:
-
- The control will display:
- When the control valve is left in this position for 60 seconds, the holiday mode is now activated. The unit will not regenerate.
- The holiday program ends when a flow rate greater than 1.5 gallons is measured with the meter or when the
SCROLL button is pushed. In either of these cases the unit will start an immediate regeneration.
- Press the
SCROLL button to advance to the next setting.
- 4. Immediate Regeneration Mode:
-
- The control will display:
- If the control valve is left in this position, the timer will countdown to 0, starting a regeneration.
- To avoid an immediate regeneration, push the
SCROLL button before the timer has reached 0.
- Press the
SCROLL button to advance to the next setting
- 5. Delayed Regeneration Mode:
-
- The control will display the programmed regeneration time:
- If the control valve is left in this position, the unit will regenerate at the programmed time.
- The display will remain in this mode until the regeneration is started.
- To cancel this mode, push the
SCROLL button
Water softeners and pure water filters allow you to create purified water for drinking (bottled water, coolers) and general residential and commercial uses (showers, laundry, etc.).
|
|
|
|